Application for Chemical and Petrol Chemical process, Boilers and other industries.
Connection:From ½” to 3” flange type, JIS, ANSI, DIN rating available; special size on request
Pressure Limited: 5 kg/cm² for Plastic chamber type (PVC, PP);
7 kg/cm² for Plastic chamber type (PVDF);
20 kg/cm² for Metal chamber type (Stainless Steel);
Up to 50 kg/cm² for Metal chamber type (Stainless Steel) on request
Temperature Limited: 0~50°C for Plastic chamber type (PVC, PP);
-30~100°C for Plastic chamber type (PVDF);
-20~150°C for Metal chamber type (Stainless Steel);
-20~300°C for Metal chamber type (Stainless Steel) on request
(for this special type, if your operating temperature is ≥250°C, the Sp.Gr. must be ≥0.8)
Center to Center Length:maximum 5500mm
Accuracy:±4mm (Transmitter type: standard ±12mm; and ±6mm on request)
Indicating Case Material / Protection Class: SS304 / IP66
Indicating Strips Material: Plastic (PBT); Brass w/painting available;
the colors are Red & White (standard), and other colors option available
Switch Track Material: Aluminum
Indicating Float Material: Aluminum
Specific Gravity:for standard type: 500~2900 kg/m³
(for special type with high temperature≥250°C, the Sp.Gr. must be ≥800kg/m³)
Indicating Gauge Orientation Adjustable
Chamber Size:ø50 or ø60mm
HART® Communication:Available
Two Wire Transmitter with HART® Protocol:
−Galvanic Isolation
−Suitable for application in SIL 2 installations
Application for Chemical and Petrol Chemical process, Boilers and other industries.
Connection:From ½” to 3” flange type, JIS, ANSI, DIN rating available; special size on request
Pressure Limited: 5 kg/cm² for Plastic chamber type (PVC, PP);
7 kg/cm² for Plastic chamber type (PVDF);
20 kg/cm² for Metal chamber type (Stainless Steel);
Up to 50 kg/cm² for Metal chamber type (Stainless Steel) on request
Temperature Limited: 0~50°C for Plastic chamber type (PVC, PP);
-30~100°C for Plastic chamber type (PVDF);
-20~150°C for Metal chamber type (Stainless Steel);
-20~300°C for Metal chamber type (Stainless Steel) on request
(for this special type, if your operating temperature is ≥250°C, the Sp.Gr. must be ≥0.8)
Center to Center Length:maximum 5500mm
Accuracy:±4mm (Transmitter type: standard ±12mm; and ±6mm on request)
Indicating Case Material / Protection Class: SS304 / IP66
Indicating Strips Material: Plastic (PBT); Brass w/painting available;
the colors are Red & White (standard), and other colors option available
Switch Track Material: Aluminum
Indicating Float Material: Aluminum
Specific Gravity:for standard type: 500~2900 kg/m³
(for special type with high temperature≥250°C, the Sp.Gr. must be ≥800kg/m³)
Indicating Gauge Orientation Adjustable
Chamber Size:ø50 or ø60mm
HART® Communication:Available
Two Wire Transmitter with HART® Protocol:
−Galvanic Isolation
−Suitable for application in SIL 2 installations
Enclosure Housing: Weather proof IP65 Process Connection: 1½"~4" flange type Flange Rating: JIS, ANSI, DIN available Material: Wetted parts SS316 Temperature Limits: -20°C to +150°C Pressure Limits: 3.0 MPa...
Enclosure Housing: Explosion proof- EEx d IIC-T6; IP66 Process Connection: 1½"~4" flange type Flange Rating: JIS, ANSI, DIN available Material: Wetted parts SS316 Pressure Limits: 3.0 MPa (30 kg/cm²); option: up to 4.5 MPa...
Wetted Parts Material: SS316, SS304 available Housing Material: EDX- Aluminum alloy or SS316 EDW- SS316 or C.S with painting The Suitable S.G.: ≥0.9 for max. length 1.2M ≥0.8 for max. length 0.8M ≥0.7~0.75 for less 0.5M En...