Description
T25-S2-C 1” Motor Operated Valve
Technical Parameters:
Product size | NPT/BSP 1/2”, NPT/BSP 3/4″, NPT 1” (Optional) |
Max working pressure | 1.0MPa |
Circulation medium | Fluid, Air |
Rated voltage | DC5V, DC12V, DC24V, AC/DC9-35V, AC110V-230V (Optional) |
Wiring control methods | CR201, CR202, CR301, CR302, CR303, CR304, CR501, CR502, CR701, CR702 (Optional) |
Working current | ≤500MA |
Open/close time | ≤5 Sec |
Life time | 70000 times |
Valve Body material | Brass, Nickel plated Brass, 304 Stainless steel (Optional) |
Actuator material | Engineering Plastics |
Sealing material | EPDM & PTFE |
Actuator rotation | 90° |
Max. torque force | 2 N.M |
Cable Length | 0.5m,1.5m (Optional) |
Environment temperature | -15℃~50℃ |
Liquid temperature | 2℃~90℃ |
Manual override | No |
Indicator | Yes |
Protection class | IP67 |
Specifications:
Model | Wiring control | Working voltage | Max. torque |
T25-S2-C | CR2 01 | DC5V, DC12V, DC24V | 2N.m |
T25-S2-C | CR202 | AC/DC9-24V, AC/DC9-35V, AC110V-230V | 2N.M |
T25-S2-C | CR3 01 |
DC5V, DC12V, DC24 |
2N.m |
T25-S2-C | CR3 02 |
DC9-35V |
2N.m |
T25-S2-C | CR3 03 |
AC/DC9-35V |
2N.m |
T25-S2-C | CR3 04 |
DC5V, DC12V, DC24V, AC/DC9-35V |
2N.m |
T25-S2-C | CR5 01 | DC5V, DC12V, DC24V | 2N.M |
T25-S2-C | CR5 02 | AC/DC9-24V, AC/DC9-35V, AC110V-230V | 2N.M |
T25-S2-C | CR7 01 |
DC9V-35V |
2N.M |
T25-S2-C | CR7 02 |
DC5V, DC12V, DC24V, AC/DC9-35V |
2N.m |
T25-S2-C | CR7 03 |
DC12V, DC24V |
2N.m |
Wiring diagram
CR2 01 Wiring Diagram ( 2 wires control )
·RD connect with positive, the BK connect with negative, the valve closed, the actuator automatically power off after in place , the valve remains fully closed position
·BK connect with positive, the RD connect with negative, the valve open, the actuator automatically power off after in place, the valve remains fully open position .
﹡Suitable Working Voltage: DC5V/DC12V/DC24V
﹡Exceeding the working voltage is forbidden
CR2 02 Wiring Diagram ( 2 wires control – Spring return in case of the power failure)
·When SW is closed , the valve open. the actuator automatically power off after in place
·When SW is open, the valve closed, the actuator automatically power off after in place
﹡Suitable Working Voltage: AC/DC9-35V
﹡Exceeding the working voltage is forbidden
CR3 01 Wiring Diagram (3 wires control )
·RD & GR connect with positive, BK connect with negative
·When OPEN( RD) & SW connected , the valve open, the actuator automatically power off after in place , valve remains fully open position
·When CLOSE(GR) & SW connected, the valve closed, the actuator automatically power off after in place, valve remains fully closed position.
﹡Suitable Working Voltage: DC5V,DC12V,DC24V
﹡Exceeding the working voltage is forbidden
CR3 02 Wiring Diagram (3 wires control )
·RD connect with positive, the BK & GR connect with negative
·SW CLOSED, the valve OPEN, the actuator automatically power off after in place.
·SW OPEN, the valve CLOSED, the actuator automatically power off after in place.
﹡Suitable Working Voltage: DC9V-35V
﹡Exceeding the working voltage is forbidden
CR3 03 Wiring Diagram (3 wires control)
·RD& GR connect with positive, the BK connect with negative。
·SW CLOSED, the valve OPEN, the actuator automatically power off after in place
·SW OPEN, the valve CLOSED, the actuator automatically power off after in place.
﹡Suitable Working Voltage: AC/DC9-35V/AC110-230V
﹡Exceeding the working voltage is forbidden
CR3 04 Wiring Diagram (3 wires control)
·RD & GR connected with positive, and the BK connected with negative
·When RD & SW connected, the valve closed, the actuator automatically power off after in place , remains fully closed position
·When GR & SW connected, the valve open, the actuator automatically power off after in place , remains fully open position.
﹡Suitable Working Voltage: DC5V,DC12V,DC24V,AC/DC9-35V
﹡Exceeding the working voltage is forbidden
CR5 01 Wiring diagram ( with feedback signal)
1RD connect with positive, the BK connect with negative,the valve closed, the actuator automatically power off after in place .
2 BK connect with positive, the RD connect with negative,the valve open, the actuator automatically power off after in place .
3.BL & WT are connect when the valve open fully, YW & WT are connect when the valve closed fully
Suitable Working Voltage::DC12V,DC24V
Exceeding the working voltage is forbidden
CR502 Wiring Diagram ( 5 wires control – Spring return)
·When SW is closed , the valve open. the actuator automatically power off after in place
·When SW is open, the valve closed, the actuator automatically power off after in place BL & WT are connect when the valve open fully, YW & WT are connect when the valve cl osed fully
﹡Suitable Working Voltage: AC/DC9-24V,AC/DC110V-230V,
﹡Exceeding the working voltage is forbidden
CR7 01 Wiring Diagram ( 7 wires control with feedback signal )
—RD connect with positive
—GR connect with SW and negative wiring
— BK connect with negative wiring
—SW open. the valve open, and keeping fully open.
—SW closed. the valve closed, and keeping fully closed.
—-BL & GY connect with the valve’s fully open signal wiring
— YW & WT connect with the valve’s fully closed signal wiring.
﹡Suitable Working Voltage: DC9V-35V
﹡Exceeding the working voltage is forbidden
※ Feedback with load ability:
① The Max. off voltage: DC36V AC220V
② The Max. off current: ≦0.4A
CR7 02 Wiring Diagram ( 7 wires control with feedback signal )
1.RD & GR connect with positive, the BK connect with negative
2. When RD & SW connected, the valve open, the actuator automatically power off after the valve fully open.
3. When GR & SW connected, the valve closed, the actuator automatically power off after the valve fully closed,.
4. BL & GY connect with the valve’s fully open signal wiring
5. YW & WT connect with the valve’s fully closed signal wiring
﹡Suitable Working Voltage:DC5V,DC12V,DC24V,AC/DC9-35V
﹡Exceeding the working voltage is forbidden
※ Feedback with load ability:
① The Max. off voltage: DC36V AC220V
② The Max. off current: ≦0.4A
CR7 03 Wiring Diagram ( 7 wires control with feedback signal )
·RD& GR connect with positive, the BK connect with negative。
·SW CLOSED, the valve OPEN, the actuator automatically power off after in place
·SW OPEN, the valve CLOSED, the actuator automatically power off after in place.
·BL & GY connect with the valve’s fully open signal wiring
·YW & WT connect with the valve’s fully closed signal wiring.
﹡Suitable Working Voltage: DC12V,DC24V