Showing 1–12 of 25 results
-
Air Control Valve
Pneumatic Valve is utilized by compressed air to control the gate open and close. It can be remote controlled and good for non-pressure environment or dirty water. The air pressure setting of the air compressor shall be larger or equal to t...
Pneumatic Valve is utilized by compressed air to control the gate open and close. It can be remote controlled and good for non-pressure environment or dirty water. The air pressure setting of the air compressor shall be larger or equal to the inner fluid pressure of the pipe. Meanwhile, it is utilized with piston and diaphragm which can be against the high pressure and dirt to keep valve’s long life. There’s a cleaning opening that is easy for dirt cleaning. The installed direction can be either vertical or horizontal....
Read More>>
- Pneumatic Valve is utilized by compressed air to control the gate open and close.
- It can be remote controlled and good for non-pressure environment or dirty water.
- The air pressure setting of the air compressor shall be larger or equal to the inner fluid pressure of the pipe.
- Meanwhile, it is utilized with piston and diaphragm which can be against the high pressure and dirt to keep valve’s long life.
- There’s a cleaning opening that is easy for dirt cleaning.
- The installed direction can be either vertical or horizontal.
-
Air Vent Valve for Fire Protection
Datasheet Z-Tide Valve ATRF-Air Vent Valve for Fire Protection-ID118-658...
Datasheet Z-Tide Valve ATRF-Air Vent Valve for Fire Protection-ID118-658...
Read More>>
-
Back Pressure Valve
Back pressure chamber controls the valve gate and let gate respond, quickly and adjust pressure accurately. Pressure Adjusting Range: 1 kgf / cm2~5 kgf / cm2 4 kgf / cm2~10 kgf / cm2 RFT Back pressure...
Back pressure chamber controls the valve gate and let gate respond, quickly and adjust pressure accurately. Pressure Adjusting Range: 1 kgf / cm2~5 kgf / cm2 4 kgf / cm2~10 kgf / cm2 RFT Back pressure...
Read More>>
Back pressure chamber controls the valve gate and let gate respond, quickly and adjust pressure accurately.
- Pressure Adjusting Range:
1 kgf / cm2~5 kgf / cm2
4 kgf / cm2~10 kgf / cm2 - Pressure Adjusting Range:
-
Fire Hydrant Pressure Reducing Valve
Datasheet Z-Tide Valve HRTL&HRTR-Fire Hydrant Pressure Reducing Valve-ID118-673...
Datasheet Z-Tide Valve HRTL&HRTR-Fire Hydrant Pressure Reducing Valve-ID118-673...
Read More>>
-
Float Valve with Float Ball Switch
Datasheet BTF&BFF-Z-Tide Float Valve Piston with Pilot Design-ID93-523...
Datasheet BTF&BFF-Z-Tide Float Valve Piston with Pilot Design-ID93-523...
Read More>>
-
Foot Valve with Lever
Datasheet Z-Tide Valve FVT&FVF-Foot Valve with Lever-ID118-738...
Datasheet Z-Tide Valve FVT&FVF-Foot Valve with Lever-ID118-738...
Read More>>
-
Gate Valve
Datasheet Z-Tide Valve HGO-UL OS&Y Gate Valve-ID123-688...
Datasheet Z-Tide Valve HGO-UL OS&Y Gate Valve-ID123-688...
Read More>>
-
Low Pressure Type Pressure Reducing Valve
The whole set is made by stainless steeel#316, and is suitable for water, steam, acid & alkaline fluid, or oil Pressure Relief Valve is a safety. device for pipes and it is normally closed. When pressure increases to setting value, pressur...
The whole set is made by stainless steeel#316, and is suitable for water, steam, acid & alkaline fluid, or oil Pressure Relief Valve is a safety. device for pipes and it is normally closed. When pressure increases to setting value, pressure relief valve rapidly releases the over high pressure. When pressure returns to safety value, pressre relief valve will automatically close to ensure the safety of equipment. Pressure Adjusting Range: 0.2 kgf / cm2 ~1.5 kgf / cm2 Maximum Applied Pressure: 10 kgf/cm2 Valve Body Testing Pressure : 16 kgf/cm2 Applied Temperature:-15°C~80°C...
Read More>>
- The whole set is made by stainless steeel#316, and is suitable for water, steam, acid & alkaline fluid, or oil
- Pressure Relief Valve is a safety. device for pipes and it is normally closed. When pressure increases to setting value, pressure relief valve rapidly releases the over high pressure. When pressure returns to safety value, pressre relief valve will automatically close to ensure the safety of equipment.
- Pressure Adjusting Range:
0.2 kgf / cm2 ~1.5 kgf / cm2 - Maximum Applied Pressure: 10 kgf/cm2
- Valve Body Testing Pressure :
16 kgf/cm2 - Applied Temperature:-15°C~80°C
-
Micro Pressure Type Direct-Activated Pressure Reducing Valve
Pressure Adjusting Range: 0.03 kgf/cm2 ~0.15 kgf/cm2 Applied Temperature:-15°C~80°C Applied Fluid: water Maximum Applied Pressure: 10 kgf/cm2 Valve Body Testing Pressure:16kgf/cm2 Horizontal installed Only...
Pressure Adjusting Range: 0.03 kgf/cm2 ~0.15 kgf/cm2 Applied Temperature:-15°C~80°C Applied Fluid: water Maximum Applied Pressure: 10 kgf/cm2 Valve Body Testing Pressure:16kgf/cm2 Horizontal installed Only...
Read More>>
- Pressure Adjusting Range:
0.03 kgf/cm2 ~0.15 kgf/cm2 - Applied Temperature:-15°C~80°C
- Applied Fluid: water
- Maximum Applied Pressure:
10 kgf/cm2 - Valve Body Testing Pressure:16kgf/cm2
- Horizontal installed Only
- Pressure Adjusting Range:
-
pressure reducing valve
Pressure reducing valve can prevent pipeline breakage due to high pressure. Pressure reducing valve is installed in water supply pipeline and maintains the setting outlet pressure in main valve, regardless of the different inlet pressure. P...
Pressure reducing valve can prevent pipeline breakage due to high pressure. Pressure reducing valve is installed in water supply pipeline and maintains the setting outlet pressure in main valve, regardless of the different inlet pressure. Pressure reducing valve can be installed in water supply, air conditioning and fire control systems to maintain the setting outlet pressure....
Read More>>
- Pressure reducing valve can prevent pipeline breakage due to high pressure.
- Pressure reducing valve is installed in water supply pipeline and maintains the setting outlet pressure in main valve, regardless of the different inlet pressure.
- Pressure reducing valve can be installed in water supply, air conditioning and fire control systems to maintain the setting outlet pressure.
-
Pressure Reducing Valve for Firefighting
UL / ULC Product Category VLMT – File No. Ex 15524 First UL / ULC Listed Piston Type Pressure Reducing Valve. Controller is fixed directly and designed of non-controller conduit. It reduces the damage of the controller conduit while trans...
UL / ULC Product Category VLMT – File No. Ex 15524 First UL / ULC Listed Piston Type Pressure Reducing Valve. Controller is fixed directly and designed of non-controller conduit. It reduces the damage of the controller conduit while transporting the equipment. Pressure Adjusting Range: 30 psi~100psi (2.1 kgf/m2~7.1kgf/m2)...
Read More>>
- UL / ULC Product Category VLMT – File No. Ex 15524
- First UL / ULC Listed Piston Type Pressure Reducing Valve.
- Controller is fixed directly and designed of non-controller conduit. It reduces the damage of the controller conduit while transporting the equipment.
- Pressure Adjusting Range: 30 psi~100psi (2.1 kgf/m2~7.1kgf/m2)